How Commercial Tankless Systems Are Built Out in Kent
A commercial system is sized for the busiest hour, not the average one. The first two setups are about how units are grouped; the last three are about the building they serve.

Multi-Unit Rack Systems
A rack mounts several tankless heaters on one frame with shared water and gas headers, so they arrive as one system. Rinnai's Tankless Rack System comes with up to six of its commercial 199,000 Btu condensing units, and its 2012 launch notes said racks can be banked to 25 units. Its specs:
- Access: fits fully assembled through a 32-inch doorway.
- Venting: PVC or Rinnai's common vent system.
- Placement and fuel: indoors or outdoors, on natural gas or propane.
Manifolded Units With Backup Capacity
Units can also be hung on a wall and tied together with manifold kits. Navien's Ready-Link kits come in 30 layouts from 2 to 16 units, with water and gas manifolds, valves and flex lines included. On its NPE-A2 series, the cascade control brings the next unit on when one hits 80% of its capacity and spreads the work across them; Navien lists cascades of up to 32 units. The practical gain is backup: with one unit down for service, the rest keep running. Rinnai makes the same pitch for its racks.
Office and Retail Restrooms
Restrooms in offices and shops use little hot water, scattered across sinks. Often the answer isn't a rack at all but small electric units at each sink, covered on the point-of-use page. Where one central heater does feed a set of lavatories, Watts describes ASSE 1070 valves as the devices that cap the temperature reaching sinks and lavatories.
Warehouses and Light Industrial Sites
Shops that handle corrosive or toxic chemicals may need emergency eyewashes or showers. Washington L&I's guidance for those stations asks for tepid water, single-valve operation and a spot no more than 10 seconds or 50 feet away. Plumbed stations must be tested weekly and inspected yearly. If the station is plumbed into hot water, ask how the design keeps it tepid for the full flushing period.
Gyms and Locker-Room Showers
A locker room puts many showers on at once, which is the load a cascade is built for. Temperature control matters as much as volume. Watts sums up the standards:
- ASSE 1017: a master mixing valve at the heater, never the only control for water reaching people.
- ASSE 1069: for gang showers fed at a preset temperature through one pipe.
- ASSE 1016 / 1070: control at the individual shower or fixture.

Why Kent homeowners and businesses call Kent Tankless Water Heater
- Your details go to a single independent plumber, not a list of bidders
- The referral is free, and booking is your call
- Ask for gas line, vent and wiring costs as separate lines
- Ask which Kent and L&I permits the job needs
- Keep the down payment small and pay as work is finished
Kent Permits and Licensing for Commercial Hot Water
Kent splits commercial water heaters by fuel. Its commercial plumbing checklist says gas water heaters are permitted as mechanical work and electric ones under chapter 5 of the plumbing code, which the city enforces as the 2021 Uniform Plumbing Code with Washington amendments. The same checklist asks for the manufacturer's equipment data and installation instructions with the application. It also requires the heaters to be strapped in their upper and lower thirds.
On the gas side, Kent's mechanical checklist asks for an accessible gas shut-off within 6 feet of every gas appliance. Leave a commercial permit's intake fee unpaid for 15 days and Kent cancels the application. Who may do the plumbing in Washington is covered on the water heater repair page; gas supply sizing for a rack is on the gas line page.
Planning Upkeep Before the Rack Goes In
Commercial units run longer hours, and Rinnai's manual doubles the descaling schedule for commercial use in treated hard-water bands, and Kent's figures on the water softener page show where a building falls. Navien sizes its PeakFlow C scale system for commercial jobs up to 20 GPM. Rinnai also strongly recommends isolation valves so each heat exchanger can be flushed. Ask that the quote show them, and where the descaling pump will connect.